Loading...
 
Print

Test Points

Test points

In the iMetos3.3 board there are several test points for convenience during service, they let the user access different voltages with no need to unplug or removing anything.

                 

GND: common ground

BAT: battery voltage,

SOL: solar panel voltage

VSUP: internal voltage supply 6V

V31: internal voltage supply 3.1V (processor, hygroclip sensors...)

V54: internal voltage supply 5.4V (sensor inputs...)

LF and HF: low frequency and high frequency (for development purposes)

 

Example: if you wish to measure battery voltage, you can measure it with Voltmeter on GND and BAT test points.

 